optical_lithography
This is an old revision of the document!
Table of Contents
Description
Warnings
- Don't make mess, clean everything after use.
- Switch off the lamp of the mask aligner, it has a limited lifetime.
- It is not allowed to take masks out of the cleanroom.
To start
- Because the UV lamp needs some time to warm up, you should switch on the mask aligner first.
- Switch on power and UV source.
- Wait for 10 minutes.
- In the meanwhile you can spincoat resist and bake it.
- Switch on the hot plate now (there is a switch at the left).
- Adjust temperature with large knob.
- Desired temperature depends on the kind of resist you use.
Spin coater
The spin coater has 2 standard recipes. To change recipe, you need to operate on the keyboard of the spin coater (that has no labels anymore). The keyboard has 10 buttons in 2 rows.
| 1 | 2 |
|---|---|
| 3 | 4 |
| 5 | 6 |
| 7 | 8 |
| 9 | 10 |
To change the recipe press the buttons in the following way:
- 1 edit.
- 10 change recipe.
- 7 (-) or 8 (+) to adjust.
- 2 end edit.
- use recipe 1 or 2 for optical resist.
Hot plate
- put the sample on the hot plate and time the process.
- the time you need depends on the kind of resist.
Mask aligner
- When you can see the blue light shining from the back, the lamp is warm.
- Put the mask in the mask holder, upside down, because in this way the side with the structure on it will be in contact with your sample.
- Slide the mask holder in the mask aligner and switch knob 'mask'.
- Put your sample in and align roughly.
- There are two handles at the left. The lower one should be set to 'contact'.
- Now you can turn the upper one.
- If the sample is not perfectly aligned, you can set the lower handle to 'separation' and adjust.
- When everything is OK, set the handle to 'contact' again.
- The exposure timer should be set to 15 seconds.
- Press exposure button and help the system a little bit if it doesn't move by itself.
Development