User Tools

Site Tools


glovebox

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
glovebox [2019/06/13 07:40] – [Using the antechambers] scholmaglovebox [2023/03/21 14:29] (current) scholma
Line 15: Line 15:
 Clean your items before bringing them in the glovebox.\\ Clean your items before bringing them in the glovebox.\\
 Discuss your experiments with other glovebox users to avoid cross contamination.\\ Discuss your experiments with other glovebox users to avoid cross contamination.\\
-Flush the antechamber 3 times when loading and unloading to prevent O<sub>2</sub> and H<sub>2</sub>O contamination and unwanted chemical release respectively.\\+Flush the antechamber 3 times when loading and unloading to prevent O<sub>2</sub> and H<sub>2</sub>O contamination and unwanted chemical release.\\
 At all times it should be prevented that sharp objects are lying around, there's a high risk of piercing the gloves.\\ At all times it should be prevented that sharp objects are lying around, there's a high risk of piercing the gloves.\\
 The gloves have a maximum reach inside, do not store stuff out of reach.\\ The gloves have a maximum reach inside, do not store stuff out of reach.\\
 Clean up when done, bring in a new white solid waste trash can when full and remove old.\\ Clean up when done, bring in a new white solid waste trash can when full and remove old.\\
 +\\
 +\\
 +\\
 +\\
 +\\
 +\\
 +\\
  
 ====Using the antechambers===== ====Using the antechambers=====
Line 45: Line 52:
  
 Open the red valve on top of the glovebox, the system will try maintain the pressure in the box by letting in inert gas. Do this for 15min or so depending on the contamination you expect inside. Purging can also be done for hours if the contamination is large, but keep an eye on the pressure of the gas cylinder. Open the red valve on top of the glovebox, the system will try maintain the pressure in the box by letting in inert gas. Do this for 15min or so depending on the contamination you expect inside. Purging can also be done for hours if the contamination is large, but keep an eye on the pressure of the gas cylinder.
 +
 +====Working with thiols====
 +Thiols are the sulfur analogue of alcohols, due to the sulfur thiols can have a strong odor. When taking out used glassware or bottles that have thiol contamination they should be properly cleaned. Cleaning with IPA or water is not sufficient. There is a bleach solution in the glovebox (10 parts water 1 part Glorix), bleach will break the thiol molucules.
  
 ====Regeneration===== ====Regeneration=====
Line 64: Line 74:
  
 Make sure full cylinder is ready to go.\\ Make sure full cylinder is ready to go.\\
-Close gas cylinder\\+Close connected gas cylinder\\
 Open reducer\\ Open reducer\\
 Open vent valve on top of the glovebox (large red handle) to empty the gas line\\ Open vent valve on top of the glovebox (large red handle) to empty the gas line\\
Line 70: Line 80:
 Close the reducer\\ Close the reducer\\
 Close vent valve\\ Close vent valve\\
 +Close cylinder\\
 Unmount reducer from gas cylinder\\ Unmount reducer from gas cylinder\\
 Mount reducer to new gas cylinder\\ Mount reducer to new gas cylinder\\
glovebox.1560411605.txt.gz · Last modified: 2019/06/13 07:40 by scholma

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki